Products / Protection Relay

Relion 630 Series

ABB Relion 630 Series Protection Relays

ABB Relion 630 Series REF630 RET630 REM630 and REG630 protection relays
ABBProtection Relay

ABB Relion 630 Series covers comprehensive feeder, transformer, motor and generator protection, control and measurement with REF630, RET630, REM630 and REG630. Availability must be confirmed per project.

IEC 60255-1IEC 61850 Edition 1DNP3 TCP/IPIEC 60870-5-103

About this product

ABB Relion 630 Series was developed for demanding utility and industrial applications requiring extensive protection, control, measurement, supervision, and bay automation. The Forvis Trade scope covers four models — REF630 for feeder protection, RET630 for transformer protection, REM630 for motor protection, and REG630 for generator protection.

Platform structure

  • REF630: feeder protection and control for overhead lines and cable feeders in radial, looped, and meshed systems.
  • RET630: transformer protection and control for two-winding power transformers, step-up transformers, and generator-transformer units.
  • REM630: motor protection and control for medium and large asynchronous and synchronous motors.
  • REG630: generator protection and control for small and medium generators and generator-transformer units.

All four models share the 630 Series' extensive I/O and bay-automation platform; what differs is the protection function set and analogue interfaces specific to each application.

Model selection

REF630 is a comprehensive feeder management relay covering advanced feeder protection, earth-fault protection, fault location, bay control, extensive I/O, and optional RTD or mA interfaces.

RET630 covers transformer differential protection (87T), thermal overload protection (49), voltage protection, hot-spot and insulation-ageing monitoring, and optional automatic voltage regulation for an on-load tap changer.

REM630 covers machine differential protection (87M), thermal overload protection (49M), motor start-up supervision (48/66), frequency protection, and optional RTD or mA monitoring.

REG630 covers generator differential protection (87G), third-harmonic stator earth-fault protection (64TN), reverse power protection (32R), interconnection protection, and optional RTD or mA monitoring.

Typical applications

  • Overhead lines and cable feeders in radial, looped, and meshed networks
  • Two-winding, step-up, and generator-transformer units
  • Medium and large asynchronous and synchronous motors
  • Small and medium generators and generator-transformer units
  • Bay automation and extensive I/O applications

Availability and project verification

The reviewed official ABB sources identify REF630, RET630, REM630, and REG630 within the 630 Series. This content does not assign a commercial product status or discontinuation date. Before quotation, a new project, spare-unit request, or modernization study, confirm product availability, support scope, firmware, exact order code, and the appropriate current alternative directly for the project.

Modernization approach

A replacement or modernization study for an installed 630 Series relay should begin with the device order code, firmware, PCM600 configuration, communication architecture, analog inputs, binary I/O, and panel cut-out. A replacement must not be selected from the model name alone. Function equivalence, logic, wiring, and station communication must be checked before quotation or specification.

Technical Specifications

ApplicationsFeeder, transformer, motor and generator protection and bay control
PlatformFreely configurable and scalable withdrawable Relion 630 Series platform
CommunicationNative IEC 61850 Edition 1 with GOOSE; DNP3 TCP/IP and IEC 60870-5-103 depending on model
IEC 61850Edition 1
Sensor SupportOrder-code and model dependent; verify existing analog input modules
Arc-Flash ProtectionNot treated as a shared family function; verify installed configuration
MountingWithdrawable relay with integrated or detached HMI depending on version
Engineering SoftwareABB PCM600
Product StatusAvailability, support scope and exact version must be confirmed per project

Model Selection

ModelPlatform classMain applicationCritical verificationRecommended approach
REF630Scalable withdrawable 630 Series feeder management relayFeeder protection and bay controlNetwork earthing method, fault location, analogue inputs and bay control logicInstalled-system support requires direct hardware verification; REX640 should be evaluated first for modernization
RET630Scalable withdrawable 630 Series transformer protection relayTwo-winding transformer protection and bay controlDifferential protection, vector group, restricted earth fault, temperature monitoring and OLTC control where presentInstalled-system support requires full hardware and settings verification; REX640 should be evaluated first for modernization
REM630Scalable withdrawable 630 Series motor protection relayLarge asynchronous and synchronous motor protectionMachine differential, thermal model, starting and locked-rotor supervision, and process temperature monitoringInstalled-system support requires motor and hardware data extraction; REX640 or, depending on application, REX615 should be evaluated for modernization
REG630Scalable withdrawable 630 Series generator protection relayGenerator and generator-transformer protectionGenerator differential, stator earth-fault, reverse-power and interconnection protectionsInstalled-system support requires extracting generating-unit and connection requirements; REX640 should be evaluated first for modernization

Hardware and Integration

ModelMeasurement inputsDigital I/OSensor supportIEC 61850Installed-system check
REF630Conventional CT/VT inputsModular, scalable BI/BOConventional CT/VTEdition 1Fault location, RTD/mA option and advanced bay control
RET630Conventional CT/VT inputsModular, scalable BI/BOConventional CT/VTEdition 1Optional automatic voltage regulation, hot-spot and ageing monitoring
REM630Conventional CT/VT inputsModular, scalable BI/BOOptional RTD/mA moduleEdition 1Synchronous and asynchronous motor applications
REG630Conventional CT/VT inputsModular, scalable BI/BOOptional RTD/mA moduleEdition 1Generator-transformer unit protection and distributed generation interconnection functions

Protection Functions

ModelProtection scopeMain functions
REF630Advanced feeder, earth-fault and fault-location functions50/51, 50N/51N, 67/67N, 50BF, 79, application dependent
RET630Transformer differential, thermal, voltage and monitoring functions87T, 49, 50BF, voltage and application-dependent backup protection
REM630Machine differential, thermal and motor start-up protection87M, 49M, 48/66, 50BF, 81
REG630Generator differential, stator earth-fault, reverse-power and interconnection protection87G, 64TN, 32R, interconnection and application-dependent backup protection

Ordering Options

Article CodeHardware ClassMain ApplicationProtection ScopeProtection FunctionsMeasurement InputsDigital Inputs and OutputsSensor SupportCommunicationIEC 61850Arc-Flash ProtectionMountingSpecial FunctionsProduct Statusselection differentiatorselection note
REF630Scalable withdrawable 630 Series feeder management relayFeeder protection and bay controlAdvanced feeder, earth-fault and fault-location functions50/51, 50N/51N, 67/67N, 50BF, 79, application dependentConventional CT/VT inputsModular, scalable BI/BOConventional CT/VTIEC 61850 Edition 1, GOOSE, DNP3 TCP/IP and IEC 60870-5-103Edition 1Verify installed configurationWithdrawable; integrated or detached HMIFault location, RTD/mA option and advanced bay controlAvailability and exact version must be confirmed per projectNetwork earthing method, fault location, analogue inputs and bay control logicInstalled-system support requires direct hardware verification; REX640 should be evaluated first for modernization
RET630Scalable withdrawable 630 Series transformer protection relayTwo-winding transformer protection and bay controlTransformer differential, thermal, voltage and monitoring functions87T, 49, 50BF, voltage and application-dependent backup protectionConventional CT/VT inputsModular, scalable BI/BOConventional CT/VTIEC 61850 Edition 1, GOOSE, DNP3 TCP/IP and IEC 60870-5-103Edition 1Verify installed configurationWithdrawable; integrated or detached HMIOptional automatic voltage regulation, hot-spot and ageing monitoringAvailability and exact version must be confirmed per projectDifferential protection, vector group, restricted earth fault, temperature monitoring and OLTC control where presentInstalled-system support requires full hardware and settings verification; REX640 should be evaluated first for modernization
REM630Scalable withdrawable 630 Series motor protection relayLarge asynchronous and synchronous motor protectionMachine differential, thermal and motor start-up protection87M, 49M, 48/66, 50BF, 81Conventional CT/VT inputsModular, scalable BI/BOOptional RTD/mA moduleIEC 61850 Edition 1, GOOSE, DNP3 TCP/IP and IEC 60870-5-103Edition 1Verify installed configurationWithdrawable; integrated or detached HMISynchronous and asynchronous motor applicationsAvailability and exact version must be confirmed per projectMachine differential, thermal model, starting and locked-rotor supervision, and process temperature monitoringInstalled-system support requires motor and hardware data extraction; REX640 or, depending on application, REX615 should be evaluated for modernization
REG630Scalable withdrawable 630 Series generator protection relayGenerator and generator-transformer protectionGenerator differential, stator earth-fault, reverse-power and interconnection protection87G, 64TN, 32R, interconnection and application-dependent backup protectionConventional CT/VT inputsModular, scalable BI/BOOptional RTD/mA moduleIEC 61850 Edition 1, GOOSE and model-dependent protocolsEdition 1Verify installed configurationWithdrawable; integrated or detached HMIGenerator-transformer unit protection and distributed generation interconnection functionsAvailability and exact version must be confirmed per projectGenerator differential, stator earth-fault, reverse-power and interconnection protectionsInstalled-system support requires extracting generating-unit and connection requirements; REX640 should be evaluated first for modernization

Related Solution

Protection Relays for DSOs

Explore the solution →

Request a Quote