PowerLogic P7
PowerLogic P7 Protection and Control Platform

When a high-flexibility, modular platform is needed for demanding protection and control applications, such as primary substations or critical infrastructure, PowerLogic P7 is what we specify. Application packages cover feeder, motor, generator, transformer, line differential, busbar differential, stand-alone merging unit, and bay control, all built on the same scalable hardware with up to 104 digital inputs, IEC 61850 Edition 2.1, and advanced cybersecurity features.
About this product
PowerLogic P7 is a modular platform for protection and control applications requiring high flexibility, extensive I/O, and advanced digital integration. Its modular boards and application-oriented firmware allow the device to scale with the requirements of the installation.
Current application packages
The current selection guide includes feeder, motor, generator, transformer, stand-alone merging unit, line differential, busbar differential, and bay control applications. Options shown only as future application scope in the official range graphic must not be added as product variants until they are confirmed in the current selection and ordering documentation.
Modular hardware
Depending on configuration, PowerLogic P7 can use up to three analogue measurement modules, up to 104 digital inputs, up to 50 outputs, and up to 6 high-speed outputs. Flush, rack, and wall-mounting options with detachable HMI support are available.
Communication and digital integration
IEC 61850 Edition 2.1, IEC 61850-9-2 LE, and IEC 61869-9 can be combined with serial protocols, Ethernet, and RSTP, PRP, HSR, or failover options. PowerLogic Engineering Suite combines device and system configuration, engineering, and maintenance workflows in one tool family.
Cybersecurity and maintenance
Role-based access, secured communication, firmware signing, secure boot, and centralized security administration form part of the cybersecurity approach. Modular boards and removable wiring interfaces help reduce maintenance time.
Typical applications
- Primary and large distribution substations
- Power generation facilities
- Large motor and generator applications
- Power transformer, line, and busbar differential protection
- Digital substation and merging-unit applications
- Data centers and critical infrastructure
- Oil, gas, mining, and metals facilities
Technical Specifications
| Applications | Feeder, motor, generator, transformer, line and busbar differential, SAMU, and bay control |
| Platform | Modular hardware with application-oriented configurable firmware |
| Communication | Serial and Ethernet; optional redundant Ethernet with multiple protocols |
| IEC 61850 | Edition 2.1 with sampled-value and merging-unit support |
| Sensor Support | Conventional CT/VT and IEC 61850 sampled values depending on application |
| Arc-Flash Protection | Not specified |
| Mounting | Flush, rack, or wall mounting with detachable HMI support |
| Engineering Software | PowerLogic Engineering Suite |
| Product Status | Current |
Application Packages
| Model | Main task | Distinguishing function | Typical use |
|---|---|---|---|
| P7 Feeder | Feeder protection | Directional protection, autoreclosing, voltage and frequency supervision | Primary and critical distribution feeders |
| P7 Motor | Motor and motor differential protection | Thermal model, starting, unbalance and motor differential | Large and critical motors |
| P7 Generator | Generator and generator differential protection | Power, excitation, frequency, pole-slip and differential | Generation and cogeneration plants |
| P7 Transformer | Transformer and transformer differential protection | Differential, REF, thermal and external protection inputs | Large power transformers |
| P7 Line Differential | Line differential protection | Line differential, distance and feeder backup protection | Line and cable sections |
| P7 Busbar Differential | Busbar differential protection | Busbar differential, breaker failure and bay integration | Multi-bay busbar systems |
| P7 SAMU | Stand-alone merging unit | Acquisition and publication of sampled values | Digital substations |
| P7 Bay Control Unit | Bay control and automation | Interlocking, mimic, flexible logic and extensive I/O | Protection-independent or centralized bay control |
Protection Functions
| Model | Protection scope | Main functions |
|---|---|---|
| P7 Feeder | Configurable feeder, directional, voltage, frequency, automation, and bay control functions | 50/51, 50N/51N, 50BF, 67, 67N, 79, 81, 86 and configurable functions |
| P7 Motor | Thermal, starting, unbalance, current, motor differential, automation, and control functions | 37, 46, 48/51LR, 49, 50/51, 66, 87M and configurable functions |
| P7 Generator | Generator power, excitation, frequency, current, voltage, differential, automation, and control functions | 21G, 24, 27, 32, 40, 46, 50/51, 59, 64S, 78, 81, 87G and configurable functions |
| P7 Transformer | Transformer differential, restricted earth fault, current, voltage, thermal, automation, and control functions | 24, 26/63, 49, 50/51, 50N/51N, 64REF, 87T and configurable functions |
| P7 Line Differential | Line differential, distance-related backup, feeder backup, automation, and control functions | 21, 21FL, 50/51, 50N/51N, 67, 67N, 87L and configurable functions |
| P7 Busbar Differential | Busbar differential, breaker failure, bay integration, automation, and control functions | 50BF, 87B and configurable bay functions |
| P7 SAMU | Acquisition and publication of sampled values with optional backup protection depending on configuration | Application dependent; sampled-value and backup functions |
| P7 Bay Control Unit | Switchgear control, interlocking, automation logic, measurement, communication, and bay integration | Control and application-dependent protection functions |
Request a Consultation