Products / Protection Relay

Sepam G Series

Sepam G Series Generator Protection Relay

Sepam G Series
Schneider ElectricProtection Relay

When MV generator protection is needed — including loss of excitation, reverse power, ROCOF disconnection and differential protection — the Sepam G Series is what we specify. Model G40 covers the core generator protection suite while G82 adds ROCOF disconnection and G87/G88 provide machine differential protection for larger generating units.

IEC 60255-1IEC 60870-5-103Modbus RTU

About this product

The Schneider Electric Sepam G Series provides dedicated MV generator protection for power generation applications ranging from diesel generator sets and gas turbine generators to large hydro and thermal generating units. The series covers the complete generator protection function set including overcurrent (50/51), directional overcurrent (67), earth fault (50N/51N), directional earth fault (67N), reverse power (32), loss of excitation (40), negative sequence (46), thermal overload (49RMS), under/overvoltage (27/59), frequency (81), ROCOF disconnection and machine differential protection on higher models. Model G40 provides the core generator protection suite suitable for the majority of generator applications including embedded generation and standby generators. G82 adds ROCOF disconnection for loss-of-mains protection on generators connected to public networks. G87 provides machine differential protection (87G) plus ROCOF, and G88 extends this to machine-transformer unit differential protection (87GT) for large generating units where the generator and step-up transformer must be protected as a single differential zone. Typical applications include standby diesel generator protection in commercial buildings, data centres and hospitals, embedded generation protection at renewable energy sites connected to DSO networks, industrial cogeneration and combined heat and power installations, and utility-scale generator protection for hydro, gas turbine and thermal generating units where the appropriate model level is selected based on machine size, criticality and grid connection requirements.

Technical Specifications

modelsG40 / G82 / G87 / G88
rtd inputsup to 16
applicationMV generator protection
communicationRS485 (IEC 60870-5-103 or Modbus RTU)
ansi functions50/51/50N/51N/67/67N/32/40/46/49RMS/27/59/81/ROCOF/87G (model dependent)
rocof disconnectionG82/G87/G88
differential protectionG87/G88

Ordering Options

Article CodeDescriptionNotes
G40Core generator protection: overcurrent + directional + loss of excitation + voltage/frequency
G82G40 + ROCOF disconnection
G87Machine differential + ROCOF disconnection
G88Machine-transformer unit differential + ROCOF